Technical parameters:
1. AC current measurement (ranges / resolution / accuracy):
4,000A / 0.001A / 50Hz ~ 100Hz ± (4.0% +10)
40.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +10)
400.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% +10)
– frequency monitoring accuracy when measuring AC current in the range of 50 to 100Hz is ± (1.0% + 5) at 0.1Hz resolution
– overload protection at 420A
2. AC voltage measurement (range / resolution / accuracy):
4.000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5)
40.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% +5)
400.0V / 0.100V / 10Hz ~ 10kHz ± (0.8% +5)
600.0V / 1,000V / 10Hz ~ 10kHz ± (0.8% +5)
– frequency monitoring accuracy when measuring AC voltage in the range of 10Hz to 10kHz ± (1.0% + 5) at a resolution of 0.01Hz to 0.01kHz
– overload protection at 600Vrms
– input impedance approx. 10MGΩ
3. DC voltage measurement (range / resolution / accuracy):
400.0mV / 0.100mV / ± (0.7% +3)
4.000V / 0.001V / ± (0.5% +2)
40.00V / 0.010V / ± (0.7% +3)
400.0V / 0.100V / ± (0.7% +3)
600V / 1,000V / ± (0.7% +3)
– input impedance approx. 10MΩ
– overload protection at 600Vrms
4. Resistance measurement (ranges / resolution / accuracy):
400.0Ω / 0.1Ω / ± (1.0% +2)
4,000kΩ / 0.001kΩ / ± (0.8% +2)
40.00kΩ / 0.01kΩ / ± (0.8% +2)
400.0kΩ / 0.1kΩ / ± (0.8% +2)
4,000MΩ / 0.001MΩ / ± (2.0% +5)
40.00MΩ / 0.01MΩ / ± (2.0% +5)
– overload protection at 600 Vrms
5. Capacity measurement (ranges / resolution / accuracy):
4,000nF / 0.001nF / ± (4.0% +10)
40.00nF / 0.01nF / ± (4.0% +10)
400.0nF / 0.1knF / ± (4.0% +10)
4,000μF / 0.001μF / ± (4.0% +5)
40.00μF / 0.01μF / ± (4.0% +5)
400.0μF / 0.1μF / ± (4.0% +5)
4,000mF / 0.001mF / ± 10.0%
– overload protection at 600 Vrms
6. Temperature measurement (ranges / resolution / accuracy):
-40°C to +40°C/1°C / ±4°C
+40°C to +500°C/1°C/ ±(1.5% +5)
+500°C to +1000°C/1°C/ ±(2.0% +5)
-40°F to +104°F/1°F/ ± 6 ° F
+104°F to +932°F/1°F/ ± (2.0 +6)
+932°F to +1832°F/1°F/ ± (2.5% +4)
7. Circuit continuity check:
– if the measured resistance is less than 10Ω, the signal of the continuous circuit sounds a buzzer
– if the measured resistance is greater than 31alizace, the open circuit signal does not sound a buzzer
– open circuit voltage about 2.0V
– measurement in the range of 400Ω
– overload protection at 600 Vrms
8. Diode measurement:
– in the forward direction, the voltage drop of the semiconductor junction is less than or equal to 2V
– for a silicon junction, a typical voltage drop is 0.5 to 0.8V
– open circuit voltage about 2.2V
– measurement in the range of 4,000V
9. Contactless electric field sensing (NCV):
– allows to detect live wires in two sensitivities – EFLo and – EFHi for low voltage distribution 110V / 50 / 60Hz and 230V / 50 / 60Hz
Other parameters:
– measurement of maximum and minimum values: Yes
– HOLD: Yes
– low battery indication: Yes
– automatic power off: Yes
– battery supply 1.5 V (R03): 2pcs
– backlit display size: 37 mm x 25 mm
– product dimensions: 215 mm x 63 mm x 36 mm
– net weight of the product: 248 g
– product color: red and gray
Package contents:
– clamp multimeter UT202R: 1pc
– test leads: 1 pair
– battery 1.5 V (R03): 2pcs
– instructions for use: 1pc